模型 | LRS-100-5 | LRS-100-12 | LRS-100-15 | LRS-100-24 | LRS-100-36 | LRS-100-48 | |
产量 | 直流电压 | 5V | 12V | 15V | 24V | 36V | 48V |
额定电流 | 18A | 8.5A | 7A | 4.5A | 2.8A | 2.3A | |
当前范围 | 0〜18A | 0〜8.5A | 0〜7A | 0〜4.5A | 0〜2.8A | 0〜2.3A | |
额定功率 | 90W | 102W | 105W | 108W | 100.8W | 110.4W | |
纹波和安培;噪声 | 100mVp-P | 120mVp-P | 120mVp-P | 150mVp-P | 200mVp-P | 200mVp-P | |
直流电压ADJ。范围 | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | |
电压容差 | ± 3% | ± 2% | ± 1% | ± 1% | ± 1% | ± 1% | |
线路规则 | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | |
负载调节 | ± 2% | ± 1% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | |
设置,上升,保持时间 | 800ms,30ms,55ms / 230VAC(满载) | ||||||
输入 | 电压范围 | 90〜264VAC,127〜373VDC | |||||
频率范围 | 47〜63HZ | ||||||
交流电流 | 1.9A / 115VAC 1.2A / 230VAC | ||||||
浪涌电流 | 冷启动50A / 230VAC | ||||||
效率 | 86% | 88% | 88.50% | 90% | 90.50% | 91% | |
漏电流 | <0.75毫安/ 240VAC | ||||||
保护 | 超载 | 额定输出功率110%~150%启动过载保护 | |||||
保护类型:打嗝模式,故障条件消除后自动恢复 | |||||||
过压 | 额定输出电压115%~135%启动过压保护 | ||||||
保护类型:打嗝模式,故障状态消除后自动恢复 | |||||||
环境 | 工作温度,湿度 | -30℃〜+ 70℃(请参考“降额曲线”) | |||||
20%~90%RH无凝结 | |||||||
储存温度,湿度 | -40℃〜+ 85℃,10%~95%RH无凝结 | ||||||
承受振动 | 10~500HZ,2G10min / 1循环,每个轴60分钟 | ||||||
安全 | 耐压 | I / P-O / P:3KVAC I / P-FG:2KVAC O / P-FG:1.25KVAC | |||||
隔离电阻 | I / P-O / P,I / P-FG,O / P-FG:100Mohms / 500VDC | ||||||
适合标准 | 安全标准 | 符合UL60950-1,TUV EN60950-1,GB4943 | |||||
EMC发射 | 符合EN55022(CISPR22)B类,GB9254 B类,EN55014,EN61000-3-2,3 | ||||||
EMC抗扰度 | 符合EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-1 | ||||||
其他 | 尺寸 | 129 * 97 *30毫米(L * W * H) | |||||
重量/包装 | 0.34公斤/ 40PCS /14.6公斤/0.025米&SUP3; /0.88CUFT | ||||||
MTBF | ≥ 705K小时。 MIL-HDBK-217F(25℃) | ||||||
注意 | 1.未特别提及的所有参数均在230VAC输入,额定负载和25℃环境温度下测量。 2.波纹&通过使用12“带宽,在20MHz带宽下测量噪声。双绞线端接0.1uf& 47uf并联电容器。 3.容差:包括设置容差,线路调节和负载调节。 4.线性调节是在额定负载下从低线到高线测量的。 5.负载调节是从0%到100%额定负载测量的 6.操作高度超过2000米(6500英尺)时,环境温度降额需要5℃/ 1000米 7.电源被视为将安装到最终设备中的组件。必须重新确认最终设备仍符合EMC指 |